Spacecraft simulators currently lack adequate functionality for comprehensive human factor evaluation during cockpit design, according to a study published on June 4, 2026, in the journal A Configurable VR Spacecraft Simulator enhanced with HMI data in Microgravity.
Operations involving spacecraft and rovers are predominantly automated or controlled from the ground rather than manned directly. The NASA Human Rating standard underscores the importance of manual flight control for crew safety during unexpected failures. Historical missions have demonstrated how manual control ensures safe returns, making in-craft simulation critical for pilot preparation.
Terrestrial microgravity simulations typically last less than 30 seconds, which remains insufficient for thorough human-machine interaction studies. The proposed VR simulator integrates data from the International Space Station. This enhancement enables immersive task execution during deorbiting manoeuvres, emergency responses, and robotic arm operations while predicting task completion times in microgravity conditions.
Evaluating usability requires reliable metrics for human factors during interactive tasks. The research team deployed the Emotiv EPOC FLEX 32 Channel EEG Tracker to assess brain activity and cognitive workload. Electrodes were prepared in saline solution and arranged according to the standard 10–20 configuration.
Data collection yielded raw EEG values and average band power across theta, alpha, beta-low, beta-high, and gamma frequency bands. Researchers calculated the Task Load Index as the ratio of mean frontal midline theta energy to mean parietal alpha energy. They also tracked the Task Engagement Index using beta, alpha, and theta bands from specific electrodes.
Ocular parameters were captured using the HTC Vive Eye Pro Virtual Reality System with an integrated eye gaze tracker, alongside Tobii Pro Glasses and Pro X3 devices. The velocity threshold fixation identification method classified gaze points based on velocities in degrees per second. Gaze distribution analysis utilized the nearest neighborhood index to estimate cognitive workload dynamically.
| Category | Equipment Used | Measured Parameters |
|---|---|---|
| Brain Activity | Emotiv EPOC FLEX 32 Channel EEG Tracker | Theta, alpha, beta-low, beta-high, and gamma band power, Task Load Index |
| Gaze Tracking | HTC Vive Eye Pro and Tobii Pro Glasses | Fixations, saccades, nearest neighborhood index |
Researchers verified the normality of paired differences for each dependent parameter using the Shapiro–Wilk test. Pairwise two-tailed t-tests were then performed between datasets with the statistical significance level set at alpha equal to 0.05. Cohen’s d was calculated to measure effect size.
Test pilots participated in simulation sequences that were regularly interchanged to avoid order effects. Brief relaxation periods were allowed between consecutive simulations to ensure independent observations across data points. Analyses were executed using the Data Analysis Toolpak in MS-Excel and IBM SPSS software Version 24.
Current methods primarily utilize standard software alongside Digital Human Models that lack adequate functionality for comprehensive human factor evaluation and design optimization.
Terrestrial microgravity simulations typically last less than 30 seconds, which is insufficient for thorough human-machine interaction studies.
Analyses were performed using the Data Analysis Toolpak in MS-Excel and IBM SPSS software Version 24.
The International Space Station, orbiting at about 400 kilometres above Earth, has hosted the longest continuous human presence in space since 2 November 2000. As the largest human spacecraft ever constructed, it provides a long-term microgravity environment where studies can be performed potentially for decades, unlike terrestrial simulations that typically last less than 30 seconds.
The study was published on June 4, 2026, in A Configurable VR Spacecraft Simulator enhanced with HMI data in Microgravity.