A dry and stretchy material developed by engineers at MIT and the Singapore-MIT Alliance for Research and Technology could eliminate the need for wet hydrogel in wearable ultrasound imaging.
Ultrasound technicians typically spread a cold gel onto a patient’s skin before scanning to fill tiny gaps between the probe and the skin. While hydrogels work well in clinical settings, they dry out within a day or two and lose their ability to transmit sound waves, limiting the long-term usability of wearable devices.
“While you can always apply more gel in a hospital, for wearable devices, you need a different approach,” said Xuanhe Zhao, the Uncas and Helen Whitaker Professor of Mechanical Engineering at MIT.
“If you don't have a good interface, that will definitely stop you from developing this wearable imaging field” said co-lead author and MIT postdoc Runze Li.

“We are really aiming to address a material challenge in ultrasound imaging” said study leader Shu Wang, a postdoc in MIT's Department of Mechanical Engineering.
To solve this material challenge, the research team designed a solid, rubbery polymer that mimics the sound-propagating properties of liquid gels. Study leader Shu Wang, a postdoc in MIT’s Department of Mechanical Engineering, said that hydrogels are mostly water with a little polymer, whereas solid materials like rubber are almost entirely polymer molecules. The team set out to reduce friction between polymer chains without adding liquid or lubricant.
Engineers landed on a “bottlebrush” molecular structure consisting of a main backbone with smaller side chains sprouting away like the bristles of a pipe cleaner. Wang explained that these hairy extensions easily move around at ultrasound frequencies and do not penetrate other molecules, generating less friction as sound waves pass through.
Initial samples were too soft and crumbly like tofu, but the team reinforced the material by chemically fusing it with a second, loosely connected network of bottlebrush molecules.
Testing the Gel-Free Patch
The resulting elastomer combines soft tissue mechanics with low-loss acoustics, as described in a study published on November 19, 2026, in the journal Science. Co-lead author Runze Li emphasized that a reliable interface is essential for advancing the wearable imaging field.
To evaluate performance, the team fabricated credit card-sized samples and tested them on a synthetic model mimicking human skin and internal structures. “The sound properties stay the same. And that was the moment when we thought, oh, this material could work.” Wang says.
In mechanical tests, researchers adhered a patch to a volunteer’s chest during a treadmill run. Unlike conventional silicone rubber, which became water-logged with sweat, the new material wicked away moisture.
For field testing, the team attached a small wearable patch to a volunteer’s neck alongside a compact ultrasound transducer. The setup was connected to a portable tablet as the volunteer took a 30-minute bike ride from MIT’s campus in Cambridge, Massachusetts, to Bunker Hill and back. The device maintained continuous and accurate ultrasound imaging of the rider’s blood flow throughout the trip over steep inclines.
Future Applications in Wearable Monitoring
The research group includes Chen Gong and Won Jun Song at MIT, Zihan Tang and Ying Li at the University of Wisconsin at Madison, Chwee Teck Lim at the National University of Singapore, and Xiaodong Chen at Nanyang Technological University in Singapore. Zhao, Chen, and Lim serve as co-lead principal investigators for the SMART WITEC interdisciplinary research group.
Going forward, the team is working to streamline the fabrication process for the new material. Researchers hope to enable wearable, long-lasting ultrasound imagers that can track athlete performance and monitor patient health outside of clinical settings.
“If we want ultrasound imaging that goes beyond the clinical scenario, we need a material that lasts longer, and is easier to handle,” Li told MIT News. “And we think this really works.”
Frequently Asked Questions
What causes ultrasound waves to dissipate in solid materials?
Soft solids have more interconnected molecular structures with larger, tangled molecules that generate friction as they shift in response to incoming sound waves.
How does the bottlebrush structure reduce friction?
A bottlebrush molecule features smaller side chains sprouting from a main backbone that easily move around at ultrasound frequencies without penetrating neighboring molecules.
Founded in 1861 by William Barton Rogers to advance industrial science, MIT moved from Boston to its Cambridge campus along the Charles River in 1916.
The institute became the nation’s largest non-industrial R&D contractor during World War II through projects such as the Radiation Laboratory, and later played key roles in the Apollo Guidance Computer and the LIGO gravitational-wave detector. As of October 2026, 107 Nobel laureates, 26 Turing Award winners, and 8 Fields Medalists have been affiliated with MIT.
How long did the material maintain clear ultrasound imaging during laboratory tests?
The material maintained clear and continuous imaging for around nine days when tested on a synthetic phantom model.
Keep reading