A new open-source airflow-exposure model has been introduced to help evaluate the risk of pathogen exposure by simulating how indoor airflow affects the movement of aerosols.
The framework, detailed in a study published in PLOS ONE, couples two-dimensional steady airflow calculations with the pedestrian dynamics simulator Vadere to provide a computationally efficient alternative to complex three-dimensional computational fluid dynamics (CFD) models. The model uses the RNG k-ε RANS turbulence model to determine mean airflow and represents aerosol clouds as distinct, circular entities that move according to local velocity at their center.
To test the model’s accuracy, researchers reconstructed a 2020 COVID-19 superspreading event at an air-conditioned restaurant in Guangzhou, China. While the model correctly identified the three tables where all reported infections occurred, it also flagged additional individuals at nearby tables who were not infected, highlighting that high exposure levels increase risk but do not guarantee transmission.
The study found that while ventilation generally reduces the mean exposure of occupants compared to stagnant air, it can simultaneously push more people above a high-risk threshold by spreading pathogens beyond the immediate vicinity of an infectious individual.
A sensitivity analysis using a choir rehearsal scenario demonstrated that inlet velocity is the primary factor influencing pathogen exposure in most configurations. In a north-to-south airflow setup, increasing inlet velocity from 0.1 m/s to 1.5 m/s reduced mean exposure significantly, though the number of highly exposed agents only dropped below the no-ventilation baseline when velocities exceeded approximately 1.1 m/s.
| Configuration | Mean Exposure | Highly Exposed Agents |
|---|---|---|
| No-airflow | 962 | 31.7 |
| North-to-south | 490 | 34.6 |
| North-to-west | 535 | 37.5 |
| North-to-north | 468 | 33.3 |
In their research, the authors propose a method for modelling airborne transmission of SARS-CoV-2 at a local scale. The study establishes a threshold for high-risk scenarios, defined as the quantity of pathogens an agent would inhale within 10 minutes while sitting 1.5 meters from an infectious individual, a benchmark the Robert Koch Institute classifies as high risk.
The researchers demonstrated that without dispersion, aerosol clouds remain strictly confined to the primary airflow path. Exposure levels rise sharply at core locations, such as table B, where figures jump significantly, but collapse by more than an order of magnitude at distant tables, such as T17 and T18.
The study, authored by Simon Rahn, Marion Gödel, Gerta Köster, and Gesine Hofinger, notes that the model relies on assumptions such as steady-state flow and two-dimensional horizontal airflow patterns, which are most appropriate for mechanically ventilated spaces. The researchers caution that for highly dynamic environments where movement disrupts indoor flow structures, separate, more intensive analysis would be required.